Superseded
Standard amendment
Historical
IEEE 802.3af:2003
IEEEE Standard for Information Technology - Telecommunications and Information Exchange Between Systems - Local and Metropolitan Area Networks - Specific Requirements - Part 3: Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Layer Specifications - Data Terminal Equipment (DTE) Power Via Media Dependent Interface (MDI)
Summary
Amendment Standard - Superseded.
This amendment is based on the current edition of IEEE Std 802.3-2002 plus changes incorporated by IEEE Std 802.3ae-2002. Abstract: Support for optionally powering a 10BASE-T, 100BASE-TX or 1000BASE-T DTE device via the Power Interface (PI) using physical layers defined in Clauses 14, 25, and 40. The Power Sourcing Equipment (PSE) is located at an end point or mid-span, separate from and between the MDIs, and provides power to the Powered Device (PD) over the Link Section. The PSE detection protocol distinguishes a compatible PD from non-compatible devices and precludes the application of power and possible damage to non-compatible devices. The PSE monitors the Maintain Power Signature (MPS)and removes power when it is no longer requested or required. Optional management function requirements are specified.
Define methodology for the provision of power via balanced cabling to connected Data Terminal Equipment with 802.3 interfaces. The amount of power will be limited by cabling physics and regulatory considerations. Compatibility with existing equipment will be considered.
To provide power for a new class of devices with 802.3 interfaces enabled by progress in silicon technology. These devices are characterized by low power requirements and LAN connectivity.
This amendment is based on the current edition of IEEE Std 802.3-2002 plus changes incorporated by IEEE Std 802.3ae-2002. Abstract: Support for optionally powering a 10BASE-T, 100BASE-TX or 1000BASE-T DTE device via the Power Interface (PI) using physical layers defined in Clauses 14, 25, and 40. The Power Sourcing Equipment (PSE) is located at an end point or mid-span, separate from and between the MDIs, and provides power to the Powered Device (PD) over the Link Section. The PSE detection protocol distinguishes a compatible PD from non-compatible devices and precludes the application of power and possible damage to non-compatible devices. The PSE monitors the Maintain Power Signature (MPS)and removes power when it is no longer requested or required. Optional management function requirements are specified.
Define methodology for the provision of power via balanced cabling to connected Data Terminal Equipment with 802.3 interfaces. The amount of power will be limited by cabling physics and regulatory considerations. Compatibility with existing equipment will be considered.
To provide power for a new class of devices with 802.3 interfaces enabled by progress in silicon technology. These devices are characterized by low power requirements and LAN connectivity.
Notes
Superseded
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 06/17/2003 |
| Edition | |
| Page Count | 133 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
| Brochures |
|
Amendments modifies
08/03/2002
Superseded
Historical
Previous versions
16/07/2021
Superseded
Historical
28/05/2021
Superseded
Historical
24/02/2021
Superseded
Historical
13/03/2020
Superseded
Historical
21/04/2017
Superseded
Historical
14/10/2016
Superseded
Historical
29/07/2016
Superseded
Historical
15/07/2011
Superseded
Historical
30/10/2009
Superseded
Historical
30/10/2009
Superseded
Historical
16/10/2006
Superseded
Historical
07/09/2004
Superseded
Historical
26/08/2002
Superseded
Historical
08/03/2002
Superseded
Historical
28/09/1998
Superseded
Historical
12/10/1993
Superseded
Historical
09/11/1992
Superseded
Historical