IEEE C37.09:1979 (R1988)
IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
Summary
New IEEE Standard - Superseded.
The various tests that are made on AC high-voltage circuit breakers are summarized. Accepted methods used in making the tests are described, and the tests that will demonstrate ratings under ANSI/IEEE standards are specified. The following categories of tests are considered: design tests, production tests, tests after delivery, field tests, and conformance tests.
This test procedure summarizes the various tests which are made on ac high-voltage circuit breakers, describes accepted methods used in making the tests, and specifies the tests which will demonstrate ratings under ANSI/IEEE standards. It does not preclude the use of other equivalent or more effective methods of demonstrating ratings.
The tests are divided into the following classifications
--Design tests
--Production tests
--Tests after delivery
--Field tests
--Conformance tests
The purposes of the test procedure are:1) To establish that a circuit breaker of the design on test can perform satisfactorily, both electrically and mechanically, up to the ratings assigned to it; 2) To establish that production breakers have been adequately tested during manufacture and after assembly and that the breakers have characteristics essentially the same as the breaker of identical design which was subjected to design tests
The various tests that are made on AC high-voltage circuit breakers are summarized. Accepted methods used in making the tests are described, and the tests that will demonstrate ratings under ANSI/IEEE standards are specified. The following categories of tests are considered: design tests, production tests, tests after delivery, field tests, and conformance tests.
This test procedure summarizes the various tests which are made on ac high-voltage circuit breakers, describes accepted methods used in making the tests, and specifies the tests which will demonstrate ratings under ANSI/IEEE standards. It does not preclude the use of other equivalent or more effective methods of demonstrating ratings.
The tests are divided into the following classifications
--Design tests
--Production tests
--Tests after delivery
--Field tests
--Conformance tests
The purposes of the test procedure are:1) To establish that a circuit breaker of the design on test can perform satisfactorily, both electrically and mechanically, up to the ratings assigned to it; 2) To establish that production breakers have been adequately tested during manufacture and after assembly and that the breakers have characteristics essentially the same as the breaker of identical design which was subjected to design tests
Notes
Superseded
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 11/28/1980 |
| Confirmation Date | 10/20/1988 |
| Edition | |
| Page Count | 60 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
| Brochures |
|
No products.
Previous versions
11/04/2019
Active
, Modified
Most Recent
02/05/2007
Superseded
, Confirmed
Historical
16/09/2005
Superseded
, Confirmed
Historical
28/03/2000
Superseded
, Confirmed
Historical
12/06/1992
Superseded
Historical
11/08/1991
Superseded
Historical
18/11/1985
Superseded
, Confirmed
Historical
30/06/1984
Superseded
Historical
28/11/1980
Superseded
, Confirmed
Historical