IEEE C37.30.1:2011
IEEE Standard Requirements for AC High-Voltage Air Switches Rated Above 1000 V
Summary
New IEEE Standard - Inactive-Reserved.
Required ratings, construction requirements, design test requirements, applications, and suggested practices for all high-voltage enclosed indoor and outdoor and non-enclosed indoor and outdoor switches rated above 1000 V are specified. This includes ratings and requirements for such switches as disconnecting, selector, horn-gap, and grounding for manual and power operation, except for interrupter switches, distribution-enclosed single-pole air switches, and distribution cutouts fitted with disconnecting blades. Supersedes IEEE Std C37.30-1997, IEEE Std C37.32-2002, IEEE Std C37.34-1994, IEEE Std C37.35-1995, IEEE Std C37.36b-1990, IEEE Std C37.37-1996.
This standard covers preferred ratings; construction and testing requirements; and application, loading, installation, operation, and maintenance guidelines for all high-voltage enclosed and non-enclosed, indoor and outdoor air switches rated in excess of 1000 V. This includes such switch types as disconnect, horn-gap, fault-initiation, and ground for manual or power operation. The following switch types are not covered by this standard: interrupter switches, distribution cutouts fitted with disconnecting blades, and switches used in metal-enclosed and pad-mounted switchgear. This standard also does not apply to load-break separable insulated connectors, circuit breakers, circuit switchers, or reclosers.
The purpose of this standard is to provide a basic standard for air switches.
Required ratings, construction requirements, design test requirements, applications, and suggested practices for all high-voltage enclosed indoor and outdoor and non-enclosed indoor and outdoor switches rated above 1000 V are specified. This includes ratings and requirements for such switches as disconnecting, selector, horn-gap, and grounding for manual and power operation, except for interrupter switches, distribution-enclosed single-pole air switches, and distribution cutouts fitted with disconnecting blades. Supersedes IEEE Std C37.30-1997, IEEE Std C37.32-2002, IEEE Std C37.34-1994, IEEE Std C37.35-1995, IEEE Std C37.36b-1990, IEEE Std C37.37-1996.
This standard covers preferred ratings; construction and testing requirements; and application, loading, installation, operation, and maintenance guidelines for all high-voltage enclosed and non-enclosed, indoor and outdoor air switches rated in excess of 1000 V. This includes such switch types as disconnect, horn-gap, fault-initiation, and ground for manual or power operation. The following switch types are not covered by this standard: interrupter switches, distribution cutouts fitted with disconnecting blades, and switches used in metal-enclosed and pad-mounted switchgear. This standard also does not apply to load-break separable insulated connectors, circuit breakers, circuit switchers, or reclosers.
The purpose of this standard is to provide a basic standard for air switches.
Notes
Inactive-Reserved
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 03/23/2012 |
| Cancellation Date | 03/24/2022 |
| Edition | |
| Page Count | 108 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |