IEEE C37.20.1:2002 (R2007)
IEEE Standard for Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear
Summary
Revision Standard - Superseded.
Low-voltage metal-enclosed switchgear-which contains either stationary or drawout, manually
or electrically operated low-voltage ac or dc power circuit breakers in individual grounded metal
compartments, in three-pole, two-pole, or single-pole construction is covered. Rated maximum voltage
levels are 254V, 508V, or 635V (ac) and 300/325V, 800V, 1000V, 1200V, 1600V, or 3200V (dc). The
preferred continuous current ratings of the main bus in ac designs are 1600A, 2000A, 3000A, 3200A,
4000A, or 5000A. For dc designs, the preferred ratings are 1600A, 2000A, 2500A, 3000A, 4000A, 5000A,
6000A, 8000A, 10000A, or 12000A. The switchgear may also contain associated control, instruments,
metering, protective, and regulating devices as necessary. The standard deals with service conditions, ratings, temperature limitations, and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application.
This project will provide a revision of the current C37.20.1 Standard. The current revision was issued in 1993 and reaffirmed in 1998. The equipment covered by this Standard has been and continues to be a vital element of industrial, commercial, institutional and utility electrical distribution systems.
Low-voltage metal-enclosed switchgear-which contains either stationary or drawout, manually
or electrically operated low-voltage ac or dc power circuit breakers in individual grounded metal
compartments, in three-pole, two-pole, or single-pole construction is covered. Rated maximum voltage
levels are 254V, 508V, or 635V (ac) and 300/325V, 800V, 1000V, 1200V, 1600V, or 3200V (dc). The
preferred continuous current ratings of the main bus in ac designs are 1600A, 2000A, 3000A, 3200A,
4000A, or 5000A. For dc designs, the preferred ratings are 1600A, 2000A, 2500A, 3000A, 4000A, 5000A,
6000A, 8000A, 10000A, or 12000A. The switchgear may also contain associated control, instruments,
metering, protective, and regulating devices as necessary. The standard deals with service conditions, ratings, temperature limitations, and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application.
This project will provide a revision of the current C37.20.1 Standard. The current revision was issued in 1993 and reaffirmed in 1998. The equipment covered by this Standard has been and continues to be a vital element of industrial, commercial, institutional and utility electrical distribution systems.
Notes
Superseded
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 10/09/2002 |
| Confirmation Date | 09/27/2007 |
| Edition | |
| Page Count | 55 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
| Brochures |
|
Amendments replaces
05/05/1994
Superseded
, Confirmed
Historical
Previous versions
09/10/2002
Superseded
, Confirmed
Historical
05/05/1994
Superseded
, Confirmed
Historical
29/06/1987
Superseded
, Confirmed
Historical