Active
Standard
Most Recent
IEEE C37.13:2024
IEEE Draft Standard for Low-Voltage AC (1058 V and Below) Power Circuit Breakers Used in Enclosures
Summary
Revision Standard - Active - Draft.
The following enclosed 37 low-voltage ac power circuit breakers are covered in this standard: a) stationary or drawout type of two-, three-, or four-pole construction, with one or more rated maximum voltages of 1058 V, 730 V, 635 V (600 V for units incorporating fuses), 508 V, or 254 V for application on systems having nominal voltages of 1000 V, 690 V, 600 V, 480 V, or 240 V; b) unfused or fused circuit breakers; c) manually or power operated; and d) with or without electromechanical or electronic trip devices. Service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, application, and the preferred ratings are discussed in this standard.
This standard covers the following types and preferred ratings for enclosed low-voltage ac power circuit breakers: a) Stationary or drawout type of two-, three-, or four-pole construction with one or more rated maximum voltages of 1058 V, 730 V, 635 V (600 V for units incorporating fuses), 508 V, or 254 V for application on systems having nominal voltages of 1000 V, 690 V, 600 V, 480 V, or 240 V respectively b) Unfused or fused type c) Manually operated or power operated, with or without a trip system d) Fused drawout assemblies consisting of current-limiting fuses in a drawout assembly intended to be connected in series with a low-voltage ac power circuit breaker to form a nonintegrally fused circuit breaker; In this standard, the term circuit breaker shall mean enclosed low-voltage ac power circuit breaker, either fused or unfused. The term unfused circuit breaker shall mean a circuit breaker without either integrally or nonintegrally mounted fuses, and the term fused circuit breaker shall mean a circuit breaker incorporating current-limiting fuses, whether integrally mounted or nonintegrally mounted.
This standard a) Establishes minimal functional requirements b) Establishes preferred rating structure c) Provides preferred ratings
The following enclosed 37 low-voltage ac power circuit breakers are covered in this standard: a) stationary or drawout type of two-, three-, or four-pole construction, with one or more rated maximum voltages of 1058 V, 730 V, 635 V (600 V for units incorporating fuses), 508 V, or 254 V for application on systems having nominal voltages of 1000 V, 690 V, 600 V, 480 V, or 240 V; b) unfused or fused circuit breakers; c) manually or power operated; and d) with or without electromechanical or electronic trip devices. Service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, application, and the preferred ratings are discussed in this standard.
This standard covers the following types and preferred ratings for enclosed low-voltage ac power circuit breakers: a) Stationary or drawout type of two-, three-, or four-pole construction with one or more rated maximum voltages of 1058 V, 730 V, 635 V (600 V for units incorporating fuses), 508 V, or 254 V for application on systems having nominal voltages of 1000 V, 690 V, 600 V, 480 V, or 240 V respectively b) Unfused or fused type c) Manually operated or power operated, with or without a trip system d) Fused drawout assemblies consisting of current-limiting fuses in a drawout assembly intended to be connected in series with a low-voltage ac power circuit breaker to form a nonintegrally fused circuit breaker; In this standard, the term circuit breaker shall mean enclosed low-voltage ac power circuit breaker, either fused or unfused. The term unfused circuit breaker shall mean a circuit breaker without either integrally or nonintegrally mounted fuses, and the term fused circuit breaker shall mean a circuit breaker incorporating current-limiting fuses, whether integrally mounted or nonintegrally mounted.
This standard a) Establishes minimal functional requirements b) Establishes preferred rating structure c) Provides preferred ratings
Notes
Active
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 12/20/2024 |
| Page Count | 91 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
| Brochures |
|
Amendments replaces
30/12/2015
Superseded
Historical
Previous versions
20/12/2024
Active
Most Recent
30/12/2015
Superseded
Historical
20/03/2009
Superseded
Historical
21/05/1991
Superseded
, Confirmed
Historical
30/11/1980
Superseded
, Confirmed
Historical
09/08/1973
Superseded
Historical
30/11/1962
Superseded
Historical