IEEE Standard for Qualifying Permanent Connections Used in Substation Grounding
Summary
Revision Standard - Superseded.
Directions and methods for qualifying permanent connections used for substation grounding are provided. Particular attention is given to the connectors used within the grid system, connectors used to join ground leads to the grid system, and connectors used to join the ground leads to equipment and structures. The purpose is to give assurance to the user that connectors meeting the requirements of this standard will perform in a satisfactory manner over the lifetime of the installation provided, that the proper connectors are selected for the application and that they are installed correctly. Parameters for testing grounding connections on aluminum, copper, steel, copper-clad steel, galvanized steel, stainless steel, and stainless-clad steel are addressed. Performance criteria are established, test procedures are provided, and mechanical, current--temperature cycling, freeze--thaw, corrosion, and fault-current tests are specified.
This standard provides direction and methods for qualifying permanent connections used for substation grounding. It particularly addresses the connectors used within the grid system, connectors used to join ground leads to the grid system, and connectors used to join the ground leads to equipment and structures.
The purpose of this standard is to give assurance to the user that connectors meeting the requirements of this standard will perform in a satisfactory manner over the lifetime of the installation provided that the proper connectors are selected for the application and that the connectors are installed correctly.
Directions and methods for qualifying permanent connections used for substation grounding are provided. Particular attention is given to the connectors used within the grid system, connectors used to join ground leads to the grid system, and connectors used to join the ground leads to equipment and structures. The purpose is to give assurance to the user that connectors meeting the requirements of this standard will perform in a satisfactory manner over the lifetime of the installation provided, that the proper connectors are selected for the application and that they are installed correctly. Parameters for testing grounding connections on aluminum, copper, steel, copper-clad steel, galvanized steel, stainless steel, and stainless-clad steel are addressed. Performance criteria are established, test procedures are provided, and mechanical, current--temperature cycling, freeze--thaw, corrosion, and fault-current tests are specified.
This standard provides direction and methods for qualifying permanent connections used for substation grounding. It particularly addresses the connectors used within the grid system, connectors used to join ground leads to the grid system, and connectors used to join the ground leads to equipment and structures.
The purpose of this standard is to give assurance to the user that connectors meeting the requirements of this standard will perform in a satisfactory manner over the lifetime of the installation provided that the proper connectors are selected for the application and that the connectors are installed correctly.
Notes
Superseded
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 06/05/1989 |
| Confirmation Date | 03/21/1996 |
| Edition | |
| Page Count | 29 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
| Brochures |
|
Amendments replaces
02/02/1984
Superseded
Historical
Previous versions
11/04/2025
Active
Most Recent
14/10/2014
Superseded
Historical
09/05/2003
Superseded
Historical
05/06/1989
Superseded
, Confirmed
Historical
02/02/1984
Superseded
Historical