IEEE Draft Guide for the Design and Installation of Cable Systems in Substations
Summary
Revision Standard - Active - Draft.
The design, installation, and protection of wire and cable systems in substations are covered in this guide, with the objective of minimizing cable failures and their consequences.
This document is a guide for the design, installation, and protection of insulated wire and cable systems in substations with the objective of minimizing cable failures and their consequences. Cable systems with voltages greater than 35kV are not covered in this guide.
The purpose of this guide is to provide guidance to the substation engineer in established practices for the application and installation of metallic and optical cables in electric power transmission and distribution substations with the objective of minimizing cable failures and their consequences. This guide emphasizes reliable electrical service and safety during the design life of the substation. Regarding cable performance, no single cable characteristic should be emphasized to the serious detriment of others. In addition to good installation, design, and construction practices, a balance of cable characteristics is necessary to provide a reliable cable system. Solutions presented in this guide may not represent the only acceptable practices for resolving problems. This guide should not be referred to or used as an industry standard or compliance standard. It is being presented to aid in the development of wire and cable system installations in substations.
The design, installation, and protection of wire and cable systems in substations are covered in this guide, with the objective of minimizing cable failures and their consequences.
This document is a guide for the design, installation, and protection of insulated wire and cable systems in substations with the objective of minimizing cable failures and their consequences. Cable systems with voltages greater than 35kV are not covered in this guide.
The purpose of this guide is to provide guidance to the substation engineer in established practices for the application and installation of metallic and optical cables in electric power transmission and distribution substations with the objective of minimizing cable failures and their consequences. This guide emphasizes reliable electrical service and safety during the design life of the substation. Regarding cable performance, no single cable characteristic should be emphasized to the serious detriment of others. In addition to good installation, design, and construction practices, a balance of cable characteristics is necessary to provide a reliable cable system. Solutions presented in this guide may not represent the only acceptable practices for resolving problems. This guide should not be referred to or used as an industry standard or compliance standard. It is being presented to aid in the development of wire and cable system installations in substations.
Notes
Active
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 05/02/2025 |
| Page Count | 245 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
| Brochures |
|
Amendments replaces
15/11/2016
Superseded
Historical
Previous versions
02/05/2025
Active
Most Recent
15/11/2016
Superseded
Historical
02/04/2008
Superseded
Historical
14/04/1993
Superseded
, Confirmed
Historical
16/09/1988
Superseded
Historical
06/10/1978
Superseded
Historical