IEEE 1309:2013
IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9 kHz to 40 GHz
Summary
Revision Standard - Inactive-Reserved.
Consensus calibration methods for electromagnetic (EM) field sensors and probes are provided. Data recording and reporting requirements are given, and methods for estimating measurement uncertainty are specified.
This standard includes calibration methods for electromagnetic field sensors and probes, excluding antennas per se, for the frequency range from 9 kHz to 40 GHz. The standard defines the characteristics, use and measurement uncertainties for electromagnetic field sensors and field probes. Areas described include: anisotropy effects, temperature effects, probe linearity effects, modulation effects, source and conductor proximity (near-field) effects, response in multi-frequency fields, partial- vs. full-immersion of probe/meter, non-purity and harmonic field effects caused by amplifiers. Specific instructions are provided for proper calibration of probes for different applications.
This standard provides consensus calibration methods for electromagnetic field sensors and probes. Calibration organizations and other users need uniform calibration methods to obtain consistent results. The calibration methods of this standard will produce results readily traceable to a national measurement institute.
Consensus calibration methods for electromagnetic (EM) field sensors and probes are provided. Data recording and reporting requirements are given, and methods for estimating measurement uncertainty are specified.
This standard includes calibration methods for electromagnetic field sensors and probes, excluding antennas per se, for the frequency range from 9 kHz to 40 GHz. The standard defines the characteristics, use and measurement uncertainties for electromagnetic field sensors and field probes. Areas described include: anisotropy effects, temperature effects, probe linearity effects, modulation effects, source and conductor proximity (near-field) effects, response in multi-frequency fields, partial- vs. full-immersion of probe/meter, non-purity and harmonic field effects caused by amplifiers. Specific instructions are provided for proper calibration of probes for different applications.
This standard provides consensus calibration methods for electromagnetic field sensors and probes. Calibration organizations and other users need uniform calibration methods to obtain consistent results. The calibration methods of this standard will produce results readily traceable to a national measurement institute.
Notes
Inactive-Reserved
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 11/22/2013 |
| Cancellation Date | 03/21/2024 |
| Edition | |
| Page Count | 111 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
| Brochures |
|
Amendments replaces
09/12/2005
Superseded
Historical
Previous versions
22/11/2013
Withdrawn
Most Recent
09/12/2005
Superseded
Historical
31/10/1996
Superseded
Historical