IEEE 1019:2004
IEEE Recommended Practice for Specifying Electric Submersible Pump Cable - Polypropylene Insulation
Summary
Revision Standard - Superseded.
Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene rubber insulation, nitrile jacket, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 96 ºC (205 ºF) for nitrile or a maximum of –10 ºC (14 ºF). Conductors, insulation, assembly and jacket, armor, requirements for testing by the manufacturer, and cable ampacity are covered.
This recommended practice establishes requirements for three-conductor round-and-flat-type oil-well cableused in supplying three-phase ac electric power to submersible pump motors. The major cable components are copper conductors, polypropylene insulation, polymeric jacket, and galvanized armor. Cables meeting the requirements of this recommended practice should be rated for voltages not exceeding 3 kV or 5 kV (phase to phase).
Perform 5 year review and updates for advances in submersible pump cable technology.
Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene rubber insulation, nitrile jacket, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 96 ºC (205 ºF) for nitrile or a maximum of –10 ºC (14 ºF). Conductors, insulation, assembly and jacket, armor, requirements for testing by the manufacturer, and cable ampacity are covered.
This recommended practice establishes requirements for three-conductor round-and-flat-type oil-well cableused in supplying three-phase ac electric power to submersible pump motors. The major cable components are copper conductors, polypropylene insulation, polymeric jacket, and galvanized armor. Cables meeting the requirements of this recommended practice should be rated for voltages not exceeding 3 kV or 5 kV (phase to phase).
Perform 5 year review and updates for advances in submersible pump cable technology.
Notes
Superseded
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 04/13/2005 |
| Edition | |
| Page Count | 36 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
| Brochures |
|
Amendments replaces
14/08/1992
Superseded
Historical
Previous versions
30/04/2013
Active
Most Recent
13/04/2005
Superseded
Historical
14/08/1992
Superseded
Historical
18/12/1984
Superseded
Historical