Active Standard
Most Recent

ASME MFC-12M-2006 (R2014)

Measurement of Fluid Flow in Closed Conduits Using Multiport Averaging Pitot Primary Elements

Summary

This Standard, provides information on the use of multiport averaging Pitot head-type devices used to measure liquids and gases. The Standard applies when the conduits are full and the flow (a) has a fully developed profile; (b) remains subsonic throughout the measurement section; (c) is steady or varies only slowly with time; (d) is considered single-phase. A differential pressure transmitter or other pressure measuring device, known as a secondary element, must be used with a multiport averaging Pitot primary element to produce a flow rate measurement. Although multiport averaging Pitot primary elements are sometimes used in noncircular conduits, such applications are beyond the scope of this Standard.

Technical characteristics

Publisher American Society of Mechanical Engineers (ASME)
Publication Date 01/01/2006
Release Date 10/09/2006
Edition 2006
Page Count 20
Themes Flow measurement
EAN ---
ISBN ---
Weight (in grams) ---
Brochures https://dev.normadoc.fr/media/cache/app_product_document_thumbnail/86/18/b07e2c17bd3821a0363c84120c2a.png https://dev.normadoc.fr/media/cache/app_product_document_thumbnail/85/6c/f355af39f2712119b6013ee66edb.png https://dev.normadoc.fr/media/cache/app_product_document_thumbnail/67/9c/464e68cef6666297efa2da366402.png https://dev.normadoc.fr/media/cache/app_product_document_thumbnail/c4/fa/ee510de3dac05094388ddec38bfd.png
No products.