GET https://dev.normadoc.fr/_partial/cart/summary?template=%40SyliusShop%2FCart%2F_widget.html.twig

Components

6 Twig Components
15 Render Count
35 ms Render Time
74.0 MiB Memory Usage

Components

Name Metadata Render Count Render Time
ProductCard
"App\Twig\Components\ProductCard"
components/ProductCard.html.twig
4 28.66ms
ProductState
"App\Twig\Components\ProductState"
components/ProductState.html.twig
4 0.79ms
ProductMostRecent
"App\Twig\Components\ProductMostRecent"
components/ProductMostRecent.html.twig
4 2.78ms
PageBanner
"App\Twig\Components\PageBanner"
components/PageBanner.html.twig
1 5.09ms
BackButton
"App\Twig\Components\BackButton"
components/BackButton.html.twig
1 0.27ms
ResponsiveCollapsibleGrid
"App\Twig\Components\ResponsiveCollapsibleGrid"
components/ResponsiveCollapsibleGrid.html.twig
1 1.03ms

Render calls

PageBanner App\Twig\Components\PageBanner 72.0 MiB 5.09 ms
Input props
[
  "backLabel" => "13 : Environment. Health protection. Safety"
  "backUrl" => "/taxons/main/ics-2277/13-environment-health-protection-safety-4334"
  "paddingClasses" => "p-2 px-lg-5 py-lg-0"
  "searchPlaceholder" => "sylius.ui.search"
  "showSearch" => "true"
  "title" => "13.060 : Water quality"
]
Attributes
[]
Component
App\Twig\Components\PageBanner {#94272
  +supTitle: null
  +title: "13.060 : Water quality"
  +subTitle: null
  +backUrl: "/taxons/main/ics-2277/13-environment-health-protection-safety-4334"
  +backLabel: "13 : Environment. Health protection. Safety"
  +customClasses: null
  +backgroundType: null
  +centered: true
  +showSearch: true
  +searchPlaceholder: "sylius.ui.search"
  +searchValue: null
  +paddingClasses: "p-2 px-lg-5 py-lg-0"
}
BackButton App\Twig\Components\BackButton 72.0 MiB 0.27 ms
Input props
[
  "url" => "/taxons/main/ics-2277/13-environment-health-protection-safety-4334"
  "label" => "13 : Environment. Health protection. Safety"
]
Attributes
[]
Component
App\Twig\Components\BackButton {#94363
  +label: "13 : Environment. Health protection. Safety"
  +url: "/taxons/main/ics-2277/13-environment-health-protection-safety-4334"
}
ResponsiveCollapsibleGrid App\Twig\Components\ResponsiveCollapsibleGrid 72.0 MiB 1.03 ms
Input props
[
  "items" => Doctrine\ORM\PersistentCollection {#8719
    #collection: Doctrine\Common\Collections\ArrayCollection {#8665 …}
    #initialized: true
    -snapshot: [ …10]
    -owner: App\Entity\Taxonomy\Taxon {#8648 …}
    -association: [ …16]
    -em: ContainerHAOxQ06\EntityManagerGhostEbeb667 {#775 …}
    -backRefFieldName: "parent"
    -typeClass: Symfony\Component\VarDumper\Caster\CutStub {#138984 …}
    -isDirty: false
  }
  "responsiveItemsPerRow" => [
    "mobile" => 2
    "tablet" => 4
    "desktop" => 6
  ]
  "responsiveVisibleRows" => [
    "mobile" => 50
    "tablet" => 25
    "desktop" => 17
  ]
  "containerClass" => "taxon-grid-subcategories-listing mb-4 px-4 px-sm-0"
  "itemTemplate" => "@BitBagSyliusElasticsearchPlugin/Shop/Product/Index/DisplayStyle/_grid_subcategory_item.html.twig"
  "showMoreText" => "app.ui.collapsible_choices.show_more"
  "showLessText" => "app.ui.collapsible_choices.show_less"
]
Attributes
[]
Component
App\Twig\Components\ResponsiveCollapsibleGrid {#94550
  +items: Doctrine\ORM\PersistentCollection {#8719
    #collection: Doctrine\Common\Collections\ArrayCollection {#8665 …}
    #initialized: true
    -snapshot: [ …10]
    -owner: App\Entity\Taxonomy\Taxon {#8648 …}
    -association: [ …16]
    -em: ContainerHAOxQ06\EntityManagerGhostEbeb667 {#775 …}
    -backRefFieldName: "parent"
    -typeClass: Symfony\Component\VarDumper\Caster\CutStub {#138984 …}
    -isDirty: false
  }
  +responsiveItemsPerRow: [
    "mobile" => 2
    "tablet" => 4
    "desktop" => 6
  ]
  +responsiveVisibleRows: [
    "mobile" => 50
    "tablet" => 25
    "desktop" => 17
  ]
  +containerClass: "taxon-grid-subcategories-listing mb-4 px-4 px-sm-0"
  +buttonClass: ""
  +itemTemplate: "@BitBagSyliusElasticsearchPlugin/Shop/Product/Index/DisplayStyle/_grid_subcategory_item.html.twig"
  +showMoreText: "app.ui.collapsible_choices.show_more"
  +showLessText: "app.ui.collapsible_choices.show_less"
  +gridItemsIdentifierClass: "responsive-collapsible-grid-item-344042"
}
ProductCard App\Twig\Components\ProductCard 74.0 MiB 10.23 ms
Input props
[
  "product" => App\Entity\Product\Product {#94978
    #id: 8963
    #code: "IEEE00001349"
    #attributes: Doctrine\ORM\PersistentCollection {#95043 …}
    #variants: Doctrine\ORM\PersistentCollection {#95041 …}
    #options: Doctrine\ORM\PersistentCollection {#95037 …}
    #associations: Doctrine\ORM\PersistentCollection {#95039 …}
    #createdAt: DateTime @1751037856 {#94966
      date: 2025-06-27 17:24:16.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754606304 {#94981
      date: 2025-08-08 00:38:24.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95053 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95241
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#94978}
        #id: 30861
        #name: "IEEE 980:1994 (R2001)"
        #slug: "ieee-980-1994-r2001-ieee00001349-240615"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil-spillage regulations and their applicability to electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical Spill Prevention Control and Countermeasure (SPCC) plan. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          It is not the intent of this guide to interpret the applicability of the governmental regulations or the oil-containment systems presented. Such interpretation is left to each individual user. The guide is intended to identify concerns, offer solutions, and let users make their own evaluations.<br />\n
          This guide applies only to insulating oil containing less than 50 ppm of PCB, which is considered to be non-PCB oil. Non-PCB oils have a PCB content that has been designated by the U.S. Environmental Protection Agency (EPA) as nonhazardous to the public, and they are not deemed to be toxic substances. While the effectiveness of the containment methods described in this guide is generally not affected by the PCB content of the oil, the regulations governing cleanup and handling of oil spills containing PCB are much more restrictive.<br />\n
          Containment and control of oil spills at electric supply substations is a concern for most electric utilities. The environmental impact of oil spills and their cleanup is governed by several federal, state, and local regulations, necessitating increased attention in substations to the need for secondary oil containment, and an SPCC plan. Beyond the threat to the environment, cleanup costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies the applicable governmental regulations, the sources of oil spills, and the typical methods used to contain and control them. It discusses the need for an SPCC plan and provides the typical plan requirements. It documents survey-reported considerations for oil-spill containment, control, and cleanup; the methods used; and their effectiveness. In June 1992 an IEEE questionnaire was sent to 190 utilities in the U.S. and Canada, surveying their experiences. Of these utilities, 59 responded. Where relevant, the survey results are referenced in the body of this<br />\n
          guide.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95051 …}
    #channels: Doctrine\ORM\PersistentCollection {#95045 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95049 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95047 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95059 …}
    -apiLastModifiedAt: DateTime @1754517600 {#94990
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#94994
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @723078000 {#94992
      date: 1992-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @984783600 {#94988
      date: 2001-03-17 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 48
    -documents: Doctrine\ORM\PersistentCollection {#95057 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95055 …}
  }
  "layout" => "vertical"
  "showPrice" => true
  "showStatusBadges" => true
  "imageFilter" => "product_listing_thumbnail"
  "additionalClasses" => "h-100 border-0"
  "hasStretchedLink" => true
  "backgroundColor" => "white"
  "hoverType" => "border-black"
]
Attributes
[]
Component
App\Twig\Components\ProductCard {#95132
  +product: App\Entity\Product\Product {#94978
    #id: 8963
    #code: "IEEE00001349"
    #attributes: Doctrine\ORM\PersistentCollection {#95043 …}
    #variants: Doctrine\ORM\PersistentCollection {#95041 …}
    #options: Doctrine\ORM\PersistentCollection {#95037 …}
    #associations: Doctrine\ORM\PersistentCollection {#95039 …}
    #createdAt: DateTime @1751037856 {#94966
      date: 2025-06-27 17:24:16.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754606304 {#94981
      date: 2025-08-08 00:38:24.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95053 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95241
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#94978}
        #id: 30861
        #name: "IEEE 980:1994 (R2001)"
        #slug: "ieee-980-1994-r2001-ieee00001349-240615"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil-spillage regulations and their applicability to electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical Spill Prevention Control and Countermeasure (SPCC) plan. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          It is not the intent of this guide to interpret the applicability of the governmental regulations or the oil-containment systems presented. Such interpretation is left to each individual user. The guide is intended to identify concerns, offer solutions, and let users make their own evaluations.<br />\n
          This guide applies only to insulating oil containing less than 50 ppm of PCB, which is considered to be non-PCB oil. Non-PCB oils have a PCB content that has been designated by the U.S. Environmental Protection Agency (EPA) as nonhazardous to the public, and they are not deemed to be toxic substances. While the effectiveness of the containment methods described in this guide is generally not affected by the PCB content of the oil, the regulations governing cleanup and handling of oil spills containing PCB are much more restrictive.<br />\n
          Containment and control of oil spills at electric supply substations is a concern for most electric utilities. The environmental impact of oil spills and their cleanup is governed by several federal, state, and local regulations, necessitating increased attention in substations to the need for secondary oil containment, and an SPCC plan. Beyond the threat to the environment, cleanup costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies the applicable governmental regulations, the sources of oil spills, and the typical methods used to contain and control them. It discusses the need for an SPCC plan and provides the typical plan requirements. It documents survey-reported considerations for oil-spill containment, control, and cleanup; the methods used; and their effectiveness. In June 1992 an IEEE questionnaire was sent to 190 utilities in the U.S. and Canada, surveying their experiences. Of these utilities, 59 responded. Where relevant, the survey results are referenced in the body of this<br />\n
          guide.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95051 …}
    #channels: Doctrine\ORM\PersistentCollection {#95045 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95049 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95047 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95059 …}
    -apiLastModifiedAt: DateTime @1754517600 {#94990
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#94994
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @723078000 {#94992
      date: 1992-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @984783600 {#94988
      date: 2001-03-17 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 48
    -documents: Doctrine\ORM\PersistentCollection {#95057 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95055 …}
  }
  +layout: "vertical"
  +showPrice: true
  +showStatusBadges: true
  +additionalClasses: "h-100 border-0"
  +linkLabel: ""
  +imageFilter: "product_listing_thumbnail"
  +hasStretchedLink: true
  +backgroundColor: "white"
  +hoverType: "border-black"
}
ProductState App\Twig\Components\ProductState 74.0 MiB 0.25 ms
Input props
[
  "product" => App\Entity\Product\Product {#94978
    #id: 8963
    #code: "IEEE00001349"
    #attributes: Doctrine\ORM\PersistentCollection {#95043 …}
    #variants: Doctrine\ORM\PersistentCollection {#95041 …}
    #options: Doctrine\ORM\PersistentCollection {#95037 …}
    #associations: Doctrine\ORM\PersistentCollection {#95039 …}
    #createdAt: DateTime @1751037856 {#94966
      date: 2025-06-27 17:24:16.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754606304 {#94981
      date: 2025-08-08 00:38:24.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95053 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95241
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#94978}
        #id: 30861
        #name: "IEEE 980:1994 (R2001)"
        #slug: "ieee-980-1994-r2001-ieee00001349-240615"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil-spillage regulations and their applicability to electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical Spill Prevention Control and Countermeasure (SPCC) plan. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          It is not the intent of this guide to interpret the applicability of the governmental regulations or the oil-containment systems presented. Such interpretation is left to each individual user. The guide is intended to identify concerns, offer solutions, and let users make their own evaluations.<br />\n
          This guide applies only to insulating oil containing less than 50 ppm of PCB, which is considered to be non-PCB oil. Non-PCB oils have a PCB content that has been designated by the U.S. Environmental Protection Agency (EPA) as nonhazardous to the public, and they are not deemed to be toxic substances. While the effectiveness of the containment methods described in this guide is generally not affected by the PCB content of the oil, the regulations governing cleanup and handling of oil spills containing PCB are much more restrictive.<br />\n
          Containment and control of oil spills at electric supply substations is a concern for most electric utilities. The environmental impact of oil spills and their cleanup is governed by several federal, state, and local regulations, necessitating increased attention in substations to the need for secondary oil containment, and an SPCC plan. Beyond the threat to the environment, cleanup costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies the applicable governmental regulations, the sources of oil spills, and the typical methods used to contain and control them. It discusses the need for an SPCC plan and provides the typical plan requirements. It documents survey-reported considerations for oil-spill containment, control, and cleanup; the methods used; and their effectiveness. In June 1992 an IEEE questionnaire was sent to 190 utilities in the U.S. and Canada, surveying their experiences. Of these utilities, 59 responded. Where relevant, the survey results are referenced in the body of this<br />\n
          guide.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95051 …}
    #channels: Doctrine\ORM\PersistentCollection {#95045 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95049 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95047 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95059 …}
    -apiLastModifiedAt: DateTime @1754517600 {#94990
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#94994
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @723078000 {#94992
      date: 1992-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @984783600 {#94988
      date: 2001-03-17 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 48
    -documents: Doctrine\ORM\PersistentCollection {#95057 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95055 …}
  }
]
Attributes
[
  "showFullLabel" => false
]
Component
App\Twig\Components\ProductState {#95248
  +product: App\Entity\Product\Product {#94978
    #id: 8963
    #code: "IEEE00001349"
    #attributes: Doctrine\ORM\PersistentCollection {#95043 …}
    #variants: Doctrine\ORM\PersistentCollection {#95041 …}
    #options: Doctrine\ORM\PersistentCollection {#95037 …}
    #associations: Doctrine\ORM\PersistentCollection {#95039 …}
    #createdAt: DateTime @1751037856 {#94966
      date: 2025-06-27 17:24:16.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754606304 {#94981
      date: 2025-08-08 00:38:24.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95053 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95241
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#94978}
        #id: 30861
        #name: "IEEE 980:1994 (R2001)"
        #slug: "ieee-980-1994-r2001-ieee00001349-240615"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil-spillage regulations and their applicability to electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical Spill Prevention Control and Countermeasure (SPCC) plan. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          It is not the intent of this guide to interpret the applicability of the governmental regulations or the oil-containment systems presented. Such interpretation is left to each individual user. The guide is intended to identify concerns, offer solutions, and let users make their own evaluations.<br />\n
          This guide applies only to insulating oil containing less than 50 ppm of PCB, which is considered to be non-PCB oil. Non-PCB oils have a PCB content that has been designated by the U.S. Environmental Protection Agency (EPA) as nonhazardous to the public, and they are not deemed to be toxic substances. While the effectiveness of the containment methods described in this guide is generally not affected by the PCB content of the oil, the regulations governing cleanup and handling of oil spills containing PCB are much more restrictive.<br />\n
          Containment and control of oil spills at electric supply substations is a concern for most electric utilities. The environmental impact of oil spills and their cleanup is governed by several federal, state, and local regulations, necessitating increased attention in substations to the need for secondary oil containment, and an SPCC plan. Beyond the threat to the environment, cleanup costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies the applicable governmental regulations, the sources of oil spills, and the typical methods used to contain and control them. It discusses the need for an SPCC plan and provides the typical plan requirements. It documents survey-reported considerations for oil-spill containment, control, and cleanup; the methods used; and their effectiveness. In June 1992 an IEEE questionnaire was sent to 190 utilities in the U.S. and Canada, surveying their experiences. Of these utilities, 59 responded. Where relevant, the survey results are referenced in the body of this<br />\n
          guide.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95051 …}
    #channels: Doctrine\ORM\PersistentCollection {#95045 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95049 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95047 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95059 …}
    -apiLastModifiedAt: DateTime @1754517600 {#94990
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#94994
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @723078000 {#94992
      date: 1992-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @984783600 {#94988
      date: 2001-03-17 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 48
    -documents: Doctrine\ORM\PersistentCollection {#95057 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95055 …}
  }
  +appearance: "state-suspended"
  +labels: [
    "Superseded"
  ]
  -stateAttributeCode: "state"
  -localeContext: Sylius\Component\Locale\Context\CompositeLocaleContext {#1833 …}
}
ProductMostRecent App\Twig\Components\ProductMostRecent 74.0 MiB 0.79 ms
Input props
[
  "product" => App\Entity\Product\Product {#94978
    #id: 8963
    #code: "IEEE00001349"
    #attributes: Doctrine\ORM\PersistentCollection {#95043 …}
    #variants: Doctrine\ORM\PersistentCollection {#95041 …}
    #options: Doctrine\ORM\PersistentCollection {#95037 …}
    #associations: Doctrine\ORM\PersistentCollection {#95039 …}
    #createdAt: DateTime @1751037856 {#94966
      date: 2025-06-27 17:24:16.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754606304 {#94981
      date: 2025-08-08 00:38:24.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95053 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95241
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#94978}
        #id: 30861
        #name: "IEEE 980:1994 (R2001)"
        #slug: "ieee-980-1994-r2001-ieee00001349-240615"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil-spillage regulations and their applicability to electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical Spill Prevention Control and Countermeasure (SPCC) plan. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          It is not the intent of this guide to interpret the applicability of the governmental regulations or the oil-containment systems presented. Such interpretation is left to each individual user. The guide is intended to identify concerns, offer solutions, and let users make their own evaluations.<br />\n
          This guide applies only to insulating oil containing less than 50 ppm of PCB, which is considered to be non-PCB oil. Non-PCB oils have a PCB content that has been designated by the U.S. Environmental Protection Agency (EPA) as nonhazardous to the public, and they are not deemed to be toxic substances. While the effectiveness of the containment methods described in this guide is generally not affected by the PCB content of the oil, the regulations governing cleanup and handling of oil spills containing PCB are much more restrictive.<br />\n
          Containment and control of oil spills at electric supply substations is a concern for most electric utilities. The environmental impact of oil spills and their cleanup is governed by several federal, state, and local regulations, necessitating increased attention in substations to the need for secondary oil containment, and an SPCC plan. Beyond the threat to the environment, cleanup costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies the applicable governmental regulations, the sources of oil spills, and the typical methods used to contain and control them. It discusses the need for an SPCC plan and provides the typical plan requirements. It documents survey-reported considerations for oil-spill containment, control, and cleanup; the methods used; and their effectiveness. In June 1992 an IEEE questionnaire was sent to 190 utilities in the U.S. and Canada, surveying their experiences. Of these utilities, 59 responded. Where relevant, the survey results are referenced in the body of this<br />\n
          guide.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95051 …}
    #channels: Doctrine\ORM\PersistentCollection {#95045 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95049 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95047 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95059 …}
    -apiLastModifiedAt: DateTime @1754517600 {#94990
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#94994
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @723078000 {#94992
      date: 1992-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @984783600 {#94988
      date: 2001-03-17 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 48
    -documents: Doctrine\ORM\PersistentCollection {#95057 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95055 …}
  }
]
Attributes
[]
Component
App\Twig\Components\ProductMostRecent {#95342
  +product: App\Entity\Product\Product {#94978
    #id: 8963
    #code: "IEEE00001349"
    #attributes: Doctrine\ORM\PersistentCollection {#95043 …}
    #variants: Doctrine\ORM\PersistentCollection {#95041 …}
    #options: Doctrine\ORM\PersistentCollection {#95037 …}
    #associations: Doctrine\ORM\PersistentCollection {#95039 …}
    #createdAt: DateTime @1751037856 {#94966
      date: 2025-06-27 17:24:16.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754606304 {#94981
      date: 2025-08-08 00:38:24.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95053 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95241
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#94978}
        #id: 30861
        #name: "IEEE 980:1994 (R2001)"
        #slug: "ieee-980-1994-r2001-ieee00001349-240615"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil-spillage regulations and their applicability to electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical Spill Prevention Control and Countermeasure (SPCC) plan. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          It is not the intent of this guide to interpret the applicability of the governmental regulations or the oil-containment systems presented. Such interpretation is left to each individual user. The guide is intended to identify concerns, offer solutions, and let users make their own evaluations.<br />\n
          This guide applies only to insulating oil containing less than 50 ppm of PCB, which is considered to be non-PCB oil. Non-PCB oils have a PCB content that has been designated by the U.S. Environmental Protection Agency (EPA) as nonhazardous to the public, and they are not deemed to be toxic substances. While the effectiveness of the containment methods described in this guide is generally not affected by the PCB content of the oil, the regulations governing cleanup and handling of oil spills containing PCB are much more restrictive.<br />\n
          Containment and control of oil spills at electric supply substations is a concern for most electric utilities. The environmental impact of oil spills and their cleanup is governed by several federal, state, and local regulations, necessitating increased attention in substations to the need for secondary oil containment, and an SPCC plan. Beyond the threat to the environment, cleanup costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies the applicable governmental regulations, the sources of oil spills, and the typical methods used to contain and control them. It discusses the need for an SPCC plan and provides the typical plan requirements. It documents survey-reported considerations for oil-spill containment, control, and cleanup; the methods used; and their effectiveness. In June 1992 an IEEE questionnaire was sent to 190 utilities in the U.S. and Canada, surveying their experiences. Of these utilities, 59 responded. Where relevant, the survey results are referenced in the body of this<br />\n
          guide.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95051 …}
    #channels: Doctrine\ORM\PersistentCollection {#95045 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95049 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95047 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95059 …}
    -apiLastModifiedAt: DateTime @1754517600 {#94990
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#94994
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @723078000 {#94992
      date: 1992-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @984783600 {#94988
      date: 2001-03-17 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 48
    -documents: Doctrine\ORM\PersistentCollection {#95057 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95055 …}
  }
  +label: "Historical"
  +icon: "historical"
  -mostRecentAttributeCode: "most_recent"
  -localeContext: Sylius\Component\Locale\Context\CompositeLocaleContext {#1833 …}
}
ProductCard App\Twig\Components\ProductCard 74.0 MiB 6.25 ms
Input props
[
  "product" => App\Entity\Product\Product {#95008
    #id: 9827
    #code: "IEEE00003012"
    #attributes: Doctrine\ORM\PersistentCollection {#95025 …}
    #variants: Doctrine\ORM\PersistentCollection {#95027 …}
    #options: Doctrine\ORM\PersistentCollection {#95062 …}
    #associations: Doctrine\ORM\PersistentCollection {#95029 …}
    #createdAt: DateTime @1751038590 {#95035
      date: 2025-06-27 17:36:30.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1753969444 {#95034
      date: 2025-07-31 15:44:04.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95017 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95555
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95008}
        #id: 34317
        #name: "IEEE/ANSI N42.18:1980 (R1991)"
        #slug: "ieee-ansi-n42-18-1980-r1991-ieee00003012-241479"
        #description: """
          New IEEE Standard - Active.<br />\n
          Installed instrumentation for measuring the quantity or rate, or both, of release of radionuclides in the effluent streams, and to provide documentation useful for scientific and legal purposes, is covered. Recommendations for the selection of instrumentation are provided. This standard applies to continuous monitors that measure normal releases, detect inadvertent releases, show general trends, and enunciate radiation levels that have exceeded predetermined values.<br />\n
          \t\t\t\t<br />\n
          This standard provides recommendations for the selection of instrumentation specific to the continuous monitoring and quantification of radioactivity in effluents released to the environment. The effluent streams considered may contain radioactive gases, liquids, particulates, or dissolved solids singly or in combination. This standard specifies detection capabilities, physical and operating limits, reliability, and calibration requirements and sets forth minimum performance requirements for effluent monitoring instrumentation. Unless otherwise specified, the criteria herein refer<br />\n
          to the total system. This standard applies only to monitoring during routine operation that includes abnormal releases.<br />\n
          Emergency situations, where additional performance capability will be required, are a matter of separate consideration.<br />\n
          Also outside the scope of this standard are sample extraction and laboratory analyses, normally used for inter comparison between monitor calibrations and laboratory analyses, and other applications for continuous monitoring instrumentation such as environmental monitoring or process control. Sampling techniques are covered in ANSI N13.1-1969, Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "American National Standard Specification and Performance of On-Site Instrumentation for Continuously Monitoring Radioactivity in Effluents, American National Standard"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95016 …}
    #channels: Doctrine\ORM\PersistentCollection {#95023 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95019 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95021 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95007 …}
    -apiLastModifiedAt: DateTime @1743289200 {#95033
      date: 2025-03-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#95032
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @312764400 {#95031
      date: 1979-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @662684400 {#95030
      date: 1991-01-01 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "N42.18"
    -bookCollection: ""
    -pageCount: 23
    -documents: Doctrine\ORM\PersistentCollection {#95002 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95000 …}
  }
  "layout" => "vertical"
  "showPrice" => true
  "showStatusBadges" => true
  "imageFilter" => "product_listing_thumbnail"
  "additionalClasses" => "h-100 border-0"
  "hasStretchedLink" => true
  "backgroundColor" => "secondary-lighter"
  "hoverType" => "border-black"
]
Attributes
[]
Component
App\Twig\Components\ProductCard {#95533
  +product: App\Entity\Product\Product {#95008
    #id: 9827
    #code: "IEEE00003012"
    #attributes: Doctrine\ORM\PersistentCollection {#95025 …}
    #variants: Doctrine\ORM\PersistentCollection {#95027 …}
    #options: Doctrine\ORM\PersistentCollection {#95062 …}
    #associations: Doctrine\ORM\PersistentCollection {#95029 …}
    #createdAt: DateTime @1751038590 {#95035
      date: 2025-06-27 17:36:30.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1753969444 {#95034
      date: 2025-07-31 15:44:04.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95017 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95555
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95008}
        #id: 34317
        #name: "IEEE/ANSI N42.18:1980 (R1991)"
        #slug: "ieee-ansi-n42-18-1980-r1991-ieee00003012-241479"
        #description: """
          New IEEE Standard - Active.<br />\n
          Installed instrumentation for measuring the quantity or rate, or both, of release of radionuclides in the effluent streams, and to provide documentation useful for scientific and legal purposes, is covered. Recommendations for the selection of instrumentation are provided. This standard applies to continuous monitors that measure normal releases, detect inadvertent releases, show general trends, and enunciate radiation levels that have exceeded predetermined values.<br />\n
          \t\t\t\t<br />\n
          This standard provides recommendations for the selection of instrumentation specific to the continuous monitoring and quantification of radioactivity in effluents released to the environment. The effluent streams considered may contain radioactive gases, liquids, particulates, or dissolved solids singly or in combination. This standard specifies detection capabilities, physical and operating limits, reliability, and calibration requirements and sets forth minimum performance requirements for effluent monitoring instrumentation. Unless otherwise specified, the criteria herein refer<br />\n
          to the total system. This standard applies only to monitoring during routine operation that includes abnormal releases.<br />\n
          Emergency situations, where additional performance capability will be required, are a matter of separate consideration.<br />\n
          Also outside the scope of this standard are sample extraction and laboratory analyses, normally used for inter comparison between monitor calibrations and laboratory analyses, and other applications for continuous monitoring instrumentation such as environmental monitoring or process control. Sampling techniques are covered in ANSI N13.1-1969, Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "American National Standard Specification and Performance of On-Site Instrumentation for Continuously Monitoring Radioactivity in Effluents, American National Standard"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95016 …}
    #channels: Doctrine\ORM\PersistentCollection {#95023 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95019 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95021 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95007 …}
    -apiLastModifiedAt: DateTime @1743289200 {#95033
      date: 2025-03-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#95032
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @312764400 {#95031
      date: 1979-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @662684400 {#95030
      date: 1991-01-01 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "N42.18"
    -bookCollection: ""
    -pageCount: 23
    -documents: Doctrine\ORM\PersistentCollection {#95002 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95000 …}
  }
  +layout: "vertical"
  +showPrice: true
  +showStatusBadges: true
  +additionalClasses: "h-100 border-0"
  +linkLabel: ""
  +imageFilter: "product_listing_thumbnail"
  +hasStretchedLink: true
  +backgroundColor: "secondary-lighter"
  +hoverType: "border-black"
}
ProductState App\Twig\Components\ProductState 74.0 MiB 0.19 ms
Input props
[
  "product" => App\Entity\Product\Product {#95008
    #id: 9827
    #code: "IEEE00003012"
    #attributes: Doctrine\ORM\PersistentCollection {#95025 …}
    #variants: Doctrine\ORM\PersistentCollection {#95027 …}
    #options: Doctrine\ORM\PersistentCollection {#95062 …}
    #associations: Doctrine\ORM\PersistentCollection {#95029 …}
    #createdAt: DateTime @1751038590 {#95035
      date: 2025-06-27 17:36:30.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1753969444 {#95034
      date: 2025-07-31 15:44:04.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95017 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95555
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95008}
        #id: 34317
        #name: "IEEE/ANSI N42.18:1980 (R1991)"
        #slug: "ieee-ansi-n42-18-1980-r1991-ieee00003012-241479"
        #description: """
          New IEEE Standard - Active.<br />\n
          Installed instrumentation for measuring the quantity or rate, or both, of release of radionuclides in the effluent streams, and to provide documentation useful for scientific and legal purposes, is covered. Recommendations for the selection of instrumentation are provided. This standard applies to continuous monitors that measure normal releases, detect inadvertent releases, show general trends, and enunciate radiation levels that have exceeded predetermined values.<br />\n
          \t\t\t\t<br />\n
          This standard provides recommendations for the selection of instrumentation specific to the continuous monitoring and quantification of radioactivity in effluents released to the environment. The effluent streams considered may contain radioactive gases, liquids, particulates, or dissolved solids singly or in combination. This standard specifies detection capabilities, physical and operating limits, reliability, and calibration requirements and sets forth minimum performance requirements for effluent monitoring instrumentation. Unless otherwise specified, the criteria herein refer<br />\n
          to the total system. This standard applies only to monitoring during routine operation that includes abnormal releases.<br />\n
          Emergency situations, where additional performance capability will be required, are a matter of separate consideration.<br />\n
          Also outside the scope of this standard are sample extraction and laboratory analyses, normally used for inter comparison between monitor calibrations and laboratory analyses, and other applications for continuous monitoring instrumentation such as environmental monitoring or process control. Sampling techniques are covered in ANSI N13.1-1969, Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "American National Standard Specification and Performance of On-Site Instrumentation for Continuously Monitoring Radioactivity in Effluents, American National Standard"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95016 …}
    #channels: Doctrine\ORM\PersistentCollection {#95023 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95019 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95021 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95007 …}
    -apiLastModifiedAt: DateTime @1743289200 {#95033
      date: 2025-03-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#95032
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @312764400 {#95031
      date: 1979-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @662684400 {#95030
      date: 1991-01-01 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "N42.18"
    -bookCollection: ""
    -pageCount: 23
    -documents: Doctrine\ORM\PersistentCollection {#95002 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95000 …}
  }
]
Attributes
[
  "showFullLabel" => false
]
Component
App\Twig\Components\ProductState {#95562
  +product: App\Entity\Product\Product {#95008
    #id: 9827
    #code: "IEEE00003012"
    #attributes: Doctrine\ORM\PersistentCollection {#95025 …}
    #variants: Doctrine\ORM\PersistentCollection {#95027 …}
    #options: Doctrine\ORM\PersistentCollection {#95062 …}
    #associations: Doctrine\ORM\PersistentCollection {#95029 …}
    #createdAt: DateTime @1751038590 {#95035
      date: 2025-06-27 17:36:30.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1753969444 {#95034
      date: 2025-07-31 15:44:04.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95017 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95555
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95008}
        #id: 34317
        #name: "IEEE/ANSI N42.18:1980 (R1991)"
        #slug: "ieee-ansi-n42-18-1980-r1991-ieee00003012-241479"
        #description: """
          New IEEE Standard - Active.<br />\n
          Installed instrumentation for measuring the quantity or rate, or both, of release of radionuclides in the effluent streams, and to provide documentation useful for scientific and legal purposes, is covered. Recommendations for the selection of instrumentation are provided. This standard applies to continuous monitors that measure normal releases, detect inadvertent releases, show general trends, and enunciate radiation levels that have exceeded predetermined values.<br />\n
          \t\t\t\t<br />\n
          This standard provides recommendations for the selection of instrumentation specific to the continuous monitoring and quantification of radioactivity in effluents released to the environment. The effluent streams considered may contain radioactive gases, liquids, particulates, or dissolved solids singly or in combination. This standard specifies detection capabilities, physical and operating limits, reliability, and calibration requirements and sets forth minimum performance requirements for effluent monitoring instrumentation. Unless otherwise specified, the criteria herein refer<br />\n
          to the total system. This standard applies only to monitoring during routine operation that includes abnormal releases.<br />\n
          Emergency situations, where additional performance capability will be required, are a matter of separate consideration.<br />\n
          Also outside the scope of this standard are sample extraction and laboratory analyses, normally used for inter comparison between monitor calibrations and laboratory analyses, and other applications for continuous monitoring instrumentation such as environmental monitoring or process control. Sampling techniques are covered in ANSI N13.1-1969, Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "American National Standard Specification and Performance of On-Site Instrumentation for Continuously Monitoring Radioactivity in Effluents, American National Standard"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95016 …}
    #channels: Doctrine\ORM\PersistentCollection {#95023 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95019 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95021 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95007 …}
    -apiLastModifiedAt: DateTime @1743289200 {#95033
      date: 2025-03-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#95032
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @312764400 {#95031
      date: 1979-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @662684400 {#95030
      date: 1991-01-01 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "N42.18"
    -bookCollection: ""
    -pageCount: 23
    -documents: Doctrine\ORM\PersistentCollection {#95002 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95000 …}
  }
  +appearance: "state-active"
  +labels: [
    "Active"
  ]
  -stateAttributeCode: "state"
  -localeContext: Sylius\Component\Locale\Context\CompositeLocaleContext {#1833 …}
}
ProductMostRecent App\Twig\Components\ProductMostRecent 74.0 MiB 0.68 ms
Input props
[
  "product" => App\Entity\Product\Product {#95008
    #id: 9827
    #code: "IEEE00003012"
    #attributes: Doctrine\ORM\PersistentCollection {#95025 …}
    #variants: Doctrine\ORM\PersistentCollection {#95027 …}
    #options: Doctrine\ORM\PersistentCollection {#95062 …}
    #associations: Doctrine\ORM\PersistentCollection {#95029 …}
    #createdAt: DateTime @1751038590 {#95035
      date: 2025-06-27 17:36:30.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1753969444 {#95034
      date: 2025-07-31 15:44:04.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95017 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95555
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95008}
        #id: 34317
        #name: "IEEE/ANSI N42.18:1980 (R1991)"
        #slug: "ieee-ansi-n42-18-1980-r1991-ieee00003012-241479"
        #description: """
          New IEEE Standard - Active.<br />\n
          Installed instrumentation for measuring the quantity or rate, or both, of release of radionuclides in the effluent streams, and to provide documentation useful for scientific and legal purposes, is covered. Recommendations for the selection of instrumentation are provided. This standard applies to continuous monitors that measure normal releases, detect inadvertent releases, show general trends, and enunciate radiation levels that have exceeded predetermined values.<br />\n
          \t\t\t\t<br />\n
          This standard provides recommendations for the selection of instrumentation specific to the continuous monitoring and quantification of radioactivity in effluents released to the environment. The effluent streams considered may contain radioactive gases, liquids, particulates, or dissolved solids singly or in combination. This standard specifies detection capabilities, physical and operating limits, reliability, and calibration requirements and sets forth minimum performance requirements for effluent monitoring instrumentation. Unless otherwise specified, the criteria herein refer<br />\n
          to the total system. This standard applies only to monitoring during routine operation that includes abnormal releases.<br />\n
          Emergency situations, where additional performance capability will be required, are a matter of separate consideration.<br />\n
          Also outside the scope of this standard are sample extraction and laboratory analyses, normally used for inter comparison between monitor calibrations and laboratory analyses, and other applications for continuous monitoring instrumentation such as environmental monitoring or process control. Sampling techniques are covered in ANSI N13.1-1969, Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "American National Standard Specification and Performance of On-Site Instrumentation for Continuously Monitoring Radioactivity in Effluents, American National Standard"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95016 …}
    #channels: Doctrine\ORM\PersistentCollection {#95023 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95019 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95021 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95007 …}
    -apiLastModifiedAt: DateTime @1743289200 {#95033
      date: 2025-03-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#95032
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @312764400 {#95031
      date: 1979-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @662684400 {#95030
      date: 1991-01-01 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "N42.18"
    -bookCollection: ""
    -pageCount: 23
    -documents: Doctrine\ORM\PersistentCollection {#95002 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95000 …}
  }
]
Attributes
[]
Component
App\Twig\Components\ProductMostRecent {#95639
  +product: App\Entity\Product\Product {#95008
    #id: 9827
    #code: "IEEE00003012"
    #attributes: Doctrine\ORM\PersistentCollection {#95025 …}
    #variants: Doctrine\ORM\PersistentCollection {#95027 …}
    #options: Doctrine\ORM\PersistentCollection {#95062 …}
    #associations: Doctrine\ORM\PersistentCollection {#95029 …}
    #createdAt: DateTime @1751038590 {#95035
      date: 2025-06-27 17:36:30.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1753969444 {#95034
      date: 2025-07-31 15:44:04.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95017 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95555
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95008}
        #id: 34317
        #name: "IEEE/ANSI N42.18:1980 (R1991)"
        #slug: "ieee-ansi-n42-18-1980-r1991-ieee00003012-241479"
        #description: """
          New IEEE Standard - Active.<br />\n
          Installed instrumentation for measuring the quantity or rate, or both, of release of radionuclides in the effluent streams, and to provide documentation useful for scientific and legal purposes, is covered. Recommendations for the selection of instrumentation are provided. This standard applies to continuous monitors that measure normal releases, detect inadvertent releases, show general trends, and enunciate radiation levels that have exceeded predetermined values.<br />\n
          \t\t\t\t<br />\n
          This standard provides recommendations for the selection of instrumentation specific to the continuous monitoring and quantification of radioactivity in effluents released to the environment. The effluent streams considered may contain radioactive gases, liquids, particulates, or dissolved solids singly or in combination. This standard specifies detection capabilities, physical and operating limits, reliability, and calibration requirements and sets forth minimum performance requirements for effluent monitoring instrumentation. Unless otherwise specified, the criteria herein refer<br />\n
          to the total system. This standard applies only to monitoring during routine operation that includes abnormal releases.<br />\n
          Emergency situations, where additional performance capability will be required, are a matter of separate consideration.<br />\n
          Also outside the scope of this standard are sample extraction and laboratory analyses, normally used for inter comparison between monitor calibrations and laboratory analyses, and other applications for continuous monitoring instrumentation such as environmental monitoring or process control. Sampling techniques are covered in ANSI N13.1-1969, Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "American National Standard Specification and Performance of On-Site Instrumentation for Continuously Monitoring Radioactivity in Effluents, American National Standard"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95016 …}
    #channels: Doctrine\ORM\PersistentCollection {#95023 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95019 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95021 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95007 …}
    -apiLastModifiedAt: DateTime @1743289200 {#95033
      date: 2025-03-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -lastUpdatedAt: DateTime @1578006000 {#95032
      date: 2020-01-03 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @312764400 {#95031
      date: 1979-11-30 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: DateTime @662684400 {#95030
      date: 1991-01-01 00:00:00.0 Europe/Paris (+01:00)
    }
    -canceledAt: null
    -edition: null
    -coreDocument: "N42.18"
    -bookCollection: ""
    -pageCount: 23
    -documents: Doctrine\ORM\PersistentCollection {#95002 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95000 …}
  }
  +label: "Most Recent"
  +icon: "check-xs"
  -mostRecentAttributeCode: "most_recent"
  -localeContext: Sylius\Component\Locale\Context\CompositeLocaleContext {#1833 …}
}
ProductCard App\Twig\Components\ProductCard 74.0 MiB 5.96 ms
Input props
[
  "product" => App\Entity\Product\Product {#95070
    #id: 10785
    #code: "IEEE00005004"
    #attributes: Doctrine\ORM\PersistentCollection {#95087 …}
    #variants: Doctrine\ORM\PersistentCollection {#95089 …}
    #options: Doctrine\ORM\PersistentCollection {#95093 …}
    #associations: Doctrine\ORM\PersistentCollection {#95091 …}
    #createdAt: DateTime @1751039281 {#95064
      date: 2025-06-27 17:48:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608190 {#95065
      date: 2025-08-08 01:09:50.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95077 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95772
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95070}
        #id: 38149
        #name: "IEEE 980:2013"
        #slug: "ieee-980-2013-ieee00005004-242437"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage regulations in electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies only to non-polychlorinated biphenyl (non-PCB) insulating oil. It is not the intent of this guide to interpret governmental regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Containment, control and mitigation of oil spills are a concern for owners and operators of electric supply substations. The environmental impact of oil spills and their mitigation is regulated by governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies some governmental regulations, sources of oil spills, and typical methods and plans to contain, control and mitigate them.<br />\n
          (Definition: &quot;Oil&quot; includes mineral oil and alternative insulating fluids)
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95079 …}
    #channels: Doctrine\ORM\PersistentCollection {#95085 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95081 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95083 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95071 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95066
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1702854000 {#95067
      date: 2023-12-18 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1387407600 {#95068
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: DateTime @1387407600 {#95069
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 55
    -documents: Doctrine\ORM\PersistentCollection {#95073 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95075 …}
  }
  "layout" => "vertical"
  "showPrice" => true
  "showStatusBadges" => true
  "imageFilter" => "product_listing_thumbnail"
  "additionalClasses" => "h-100 border-0"
  "hasStretchedLink" => true
  "backgroundColor" => "white"
  "hoverType" => "border-black"
]
Attributes
[]
Component
App\Twig\Components\ProductCard {#95752
  +product: App\Entity\Product\Product {#95070
    #id: 10785
    #code: "IEEE00005004"
    #attributes: Doctrine\ORM\PersistentCollection {#95087 …}
    #variants: Doctrine\ORM\PersistentCollection {#95089 …}
    #options: Doctrine\ORM\PersistentCollection {#95093 …}
    #associations: Doctrine\ORM\PersistentCollection {#95091 …}
    #createdAt: DateTime @1751039281 {#95064
      date: 2025-06-27 17:48:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608190 {#95065
      date: 2025-08-08 01:09:50.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95077 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95772
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95070}
        #id: 38149
        #name: "IEEE 980:2013"
        #slug: "ieee-980-2013-ieee00005004-242437"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage regulations in electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies only to non-polychlorinated biphenyl (non-PCB) insulating oil. It is not the intent of this guide to interpret governmental regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Containment, control and mitigation of oil spills are a concern for owners and operators of electric supply substations. The environmental impact of oil spills and their mitigation is regulated by governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies some governmental regulations, sources of oil spills, and typical methods and plans to contain, control and mitigate them.<br />\n
          (Definition: &quot;Oil&quot; includes mineral oil and alternative insulating fluids)
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95079 …}
    #channels: Doctrine\ORM\PersistentCollection {#95085 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95081 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95083 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95071 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95066
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1702854000 {#95067
      date: 2023-12-18 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1387407600 {#95068
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: DateTime @1387407600 {#95069
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 55
    -documents: Doctrine\ORM\PersistentCollection {#95073 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95075 …}
  }
  +layout: "vertical"
  +showPrice: true
  +showStatusBadges: true
  +additionalClasses: "h-100 border-0"
  +linkLabel: ""
  +imageFilter: "product_listing_thumbnail"
  +hasStretchedLink: true
  +backgroundColor: "white"
  +hoverType: "border-black"
}
ProductState App\Twig\Components\ProductState 74.0 MiB 0.18 ms
Input props
[
  "product" => App\Entity\Product\Product {#95070
    #id: 10785
    #code: "IEEE00005004"
    #attributes: Doctrine\ORM\PersistentCollection {#95087 …}
    #variants: Doctrine\ORM\PersistentCollection {#95089 …}
    #options: Doctrine\ORM\PersistentCollection {#95093 …}
    #associations: Doctrine\ORM\PersistentCollection {#95091 …}
    #createdAt: DateTime @1751039281 {#95064
      date: 2025-06-27 17:48:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608190 {#95065
      date: 2025-08-08 01:09:50.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95077 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95772
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95070}
        #id: 38149
        #name: "IEEE 980:2013"
        #slug: "ieee-980-2013-ieee00005004-242437"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage regulations in electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies only to non-polychlorinated biphenyl (non-PCB) insulating oil. It is not the intent of this guide to interpret governmental regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Containment, control and mitigation of oil spills are a concern for owners and operators of electric supply substations. The environmental impact of oil spills and their mitigation is regulated by governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies some governmental regulations, sources of oil spills, and typical methods and plans to contain, control and mitigate them.<br />\n
          (Definition: &quot;Oil&quot; includes mineral oil and alternative insulating fluids)
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95079 …}
    #channels: Doctrine\ORM\PersistentCollection {#95085 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95081 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95083 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95071 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95066
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1702854000 {#95067
      date: 2023-12-18 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1387407600 {#95068
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: DateTime @1387407600 {#95069
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 55
    -documents: Doctrine\ORM\PersistentCollection {#95073 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95075 …}
  }
]
Attributes
[
  "showFullLabel" => false
]
Component
App\Twig\Components\ProductState {#95790
  +product: App\Entity\Product\Product {#95070
    #id: 10785
    #code: "IEEE00005004"
    #attributes: Doctrine\ORM\PersistentCollection {#95087 …}
    #variants: Doctrine\ORM\PersistentCollection {#95089 …}
    #options: Doctrine\ORM\PersistentCollection {#95093 …}
    #associations: Doctrine\ORM\PersistentCollection {#95091 …}
    #createdAt: DateTime @1751039281 {#95064
      date: 2025-06-27 17:48:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608190 {#95065
      date: 2025-08-08 01:09:50.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95077 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95772
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95070}
        #id: 38149
        #name: "IEEE 980:2013"
        #slug: "ieee-980-2013-ieee00005004-242437"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage regulations in electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies only to non-polychlorinated biphenyl (non-PCB) insulating oil. It is not the intent of this guide to interpret governmental regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Containment, control and mitigation of oil spills are a concern for owners and operators of electric supply substations. The environmental impact of oil spills and their mitigation is regulated by governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies some governmental regulations, sources of oil spills, and typical methods and plans to contain, control and mitigate them.<br />\n
          (Definition: &quot;Oil&quot; includes mineral oil and alternative insulating fluids)
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95079 …}
    #channels: Doctrine\ORM\PersistentCollection {#95085 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95081 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95083 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95071 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95066
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1702854000 {#95067
      date: 2023-12-18 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1387407600 {#95068
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: DateTime @1387407600 {#95069
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 55
    -documents: Doctrine\ORM\PersistentCollection {#95073 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95075 …}
  }
  +appearance: "state-suspended"
  +labels: [
    "Superseded"
  ]
  -stateAttributeCode: "state"
  -localeContext: Sylius\Component\Locale\Context\CompositeLocaleContext {#1833 …}
}
ProductMostRecent App\Twig\Components\ProductMostRecent 74.0 MiB 0.66 ms
Input props
[
  "product" => App\Entity\Product\Product {#95070
    #id: 10785
    #code: "IEEE00005004"
    #attributes: Doctrine\ORM\PersistentCollection {#95087 …}
    #variants: Doctrine\ORM\PersistentCollection {#95089 …}
    #options: Doctrine\ORM\PersistentCollection {#95093 …}
    #associations: Doctrine\ORM\PersistentCollection {#95091 …}
    #createdAt: DateTime @1751039281 {#95064
      date: 2025-06-27 17:48:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608190 {#95065
      date: 2025-08-08 01:09:50.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95077 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95772
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95070}
        #id: 38149
        #name: "IEEE 980:2013"
        #slug: "ieee-980-2013-ieee00005004-242437"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage regulations in electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies only to non-polychlorinated biphenyl (non-PCB) insulating oil. It is not the intent of this guide to interpret governmental regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Containment, control and mitigation of oil spills are a concern for owners and operators of electric supply substations. The environmental impact of oil spills and their mitigation is regulated by governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies some governmental regulations, sources of oil spills, and typical methods and plans to contain, control and mitigate them.<br />\n
          (Definition: &quot;Oil&quot; includes mineral oil and alternative insulating fluids)
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95079 …}
    #channels: Doctrine\ORM\PersistentCollection {#95085 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95081 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95083 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95071 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95066
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1702854000 {#95067
      date: 2023-12-18 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1387407600 {#95068
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: DateTime @1387407600 {#95069
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 55
    -documents: Doctrine\ORM\PersistentCollection {#95073 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95075 …}
  }
]
Attributes
[]
Component
App\Twig\Components\ProductMostRecent {#95864
  +product: App\Entity\Product\Product {#95070
    #id: 10785
    #code: "IEEE00005004"
    #attributes: Doctrine\ORM\PersistentCollection {#95087 …}
    #variants: Doctrine\ORM\PersistentCollection {#95089 …}
    #options: Doctrine\ORM\PersistentCollection {#95093 …}
    #associations: Doctrine\ORM\PersistentCollection {#95091 …}
    #createdAt: DateTime @1751039281 {#95064
      date: 2025-06-27 17:48:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608190 {#95065
      date: 2025-08-08 01:09:50.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95077 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#95772
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95070}
        #id: 38149
        #name: "IEEE 980:2013"
        #slug: "ieee-980-2013-ieee00005004-242437"
        #description: """
          Revision Standard - Superseded.<br />\n
          The significance of oil-spillage regulations and their applicability to electric supply substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage regulations in electric supply substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies only to non-polychlorinated biphenyl (non-PCB) insulating oil. It is not the intent of this guide to interpret governmental regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Containment, control and mitigation of oil spills are a concern for owners and operators of electric supply substations. The environmental impact of oil spills and their mitigation is regulated by governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate, and the adverse community response to any spill is becoming increasingly unacceptable.<br />\n
          This guide identifies some governmental regulations, sources of oil spills, and typical methods and plans to contain, control and mitigate them.<br />\n
          (Definition: &quot;Oil&quot; includes mineral oil and alternative insulating fluids)
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Superseded"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95079 …}
    #channels: Doctrine\ORM\PersistentCollection {#95085 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95081 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95083 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95071 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95066
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1702854000 {#95067
      date: 2023-12-18 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1387407600 {#95068
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: DateTime @1387407600 {#95069
      date: 2013-12-19 00:00:00.0 Europe/Paris (+01:00)
    }
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 55
    -documents: Doctrine\ORM\PersistentCollection {#95073 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95075 …}
  }
  +label: "Historical"
  +icon: "historical"
  -mostRecentAttributeCode: "most_recent"
  -localeContext: Sylius\Component\Locale\Context\CompositeLocaleContext {#1833 …}
}
ProductCard App\Twig\Components\ProductCard 74.0 MiB 6.22 ms
Input props
[
  "product" => App\Entity\Product\Product {#95100
    #id: 12075
    #code: "IEEE00007038"
    #attributes: Doctrine\ORM\PersistentCollection {#95117 …}
    #variants: Doctrine\ORM\PersistentCollection {#95119 …}
    #options: Doctrine\ORM\PersistentCollection {#95123 …}
    #associations: Doctrine\ORM\PersistentCollection {#95121 …}
    #createdAt: DateTime @1751040181 {#95095
      date: 2025-06-27 18:03:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608621 {#95096
      date: 2025-08-08 01:17:01.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95107 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#96023
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95100}
        #id: 43309
        #name: "IEEE 980:2021"
        #slug: "ieee-980-2021-ieee00007038-243727"
        #description: """
          Revision Standard - Active.<br />\n
          The significance of oil-spillage regulations and their applicability to electric substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage in electric substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies to all types of insulating oil, fuel, and other oils typical of electrical substations.<br />\n
          It is not the intent of this guide to interpret government regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Note that much of the material and information in this guide is based on discussions, experiences, and research conducted by the IEEE Oil Containment Working Group. Part of this research includes industry surveys conducted in 1992 and 2012 in an effort to determine common practices for oil containment and control in electrical substations. Although generally not discussed in the body of this guide, the detailed survey results can be found within Annex C.<br />\n
          Containment, control, and mitigation of oil spills are a concern for owners and operators of electric substations. The environmental impact of oil spills and their mitigation is regulated by some governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate and the adverse community response to any spill is becoming increasingly unacceptable. This guide identifies some governmental regulations, the sources of oil spills, and typical methods and plans used to contain, control, and mitigate them.<br />\n
          Note that use of the term “oil” in this document includes mineral oil and other alternative insulating fluids.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95109 …}
    #channels: Doctrine\ORM\PersistentCollection {#95115 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95111 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95113 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95101 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95097
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1677106800 {#95098
      date: 2023-02-23 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1650405600 {#95099
      date: 2022-04-20 00:00:00.0 Europe/Paris (+02:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 82
    -documents: Doctrine\ORM\PersistentCollection {#95103 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95105 …}
  }
  "layout" => "vertical"
  "showPrice" => true
  "showStatusBadges" => true
  "imageFilter" => "product_listing_thumbnail"
  "additionalClasses" => "h-100 border-0"
  "hasStretchedLink" => true
  "backgroundColor" => "secondary-lighter"
  "hoverType" => "border-black"
]
Attributes
[]
Component
App\Twig\Components\ProductCard {#96003
  +product: App\Entity\Product\Product {#95100
    #id: 12075
    #code: "IEEE00007038"
    #attributes: Doctrine\ORM\PersistentCollection {#95117 …}
    #variants: Doctrine\ORM\PersistentCollection {#95119 …}
    #options: Doctrine\ORM\PersistentCollection {#95123 …}
    #associations: Doctrine\ORM\PersistentCollection {#95121 …}
    #createdAt: DateTime @1751040181 {#95095
      date: 2025-06-27 18:03:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608621 {#95096
      date: 2025-08-08 01:17:01.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95107 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#96023
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95100}
        #id: 43309
        #name: "IEEE 980:2021"
        #slug: "ieee-980-2021-ieee00007038-243727"
        #description: """
          Revision Standard - Active.<br />\n
          The significance of oil-spillage regulations and their applicability to electric substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage in electric substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies to all types of insulating oil, fuel, and other oils typical of electrical substations.<br />\n
          It is not the intent of this guide to interpret government regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Note that much of the material and information in this guide is based on discussions, experiences, and research conducted by the IEEE Oil Containment Working Group. Part of this research includes industry surveys conducted in 1992 and 2012 in an effort to determine common practices for oil containment and control in electrical substations. Although generally not discussed in the body of this guide, the detailed survey results can be found within Annex C.<br />\n
          Containment, control, and mitigation of oil spills are a concern for owners and operators of electric substations. The environmental impact of oil spills and their mitigation is regulated by some governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate and the adverse community response to any spill is becoming increasingly unacceptable. This guide identifies some governmental regulations, the sources of oil spills, and typical methods and plans used to contain, control, and mitigate them.<br />\n
          Note that use of the term “oil” in this document includes mineral oil and other alternative insulating fluids.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95109 …}
    #channels: Doctrine\ORM\PersistentCollection {#95115 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95111 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95113 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95101 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95097
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1677106800 {#95098
      date: 2023-02-23 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1650405600 {#95099
      date: 2022-04-20 00:00:00.0 Europe/Paris (+02:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 82
    -documents: Doctrine\ORM\PersistentCollection {#95103 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95105 …}
  }
  +layout: "vertical"
  +showPrice: true
  +showStatusBadges: true
  +additionalClasses: "h-100 border-0"
  +linkLabel: ""
  +imageFilter: "product_listing_thumbnail"
  +hasStretchedLink: true
  +backgroundColor: "secondary-lighter"
  +hoverType: "border-black"
}
ProductState App\Twig\Components\ProductState 74.0 MiB 0.18 ms
Input props
[
  "product" => App\Entity\Product\Product {#95100
    #id: 12075
    #code: "IEEE00007038"
    #attributes: Doctrine\ORM\PersistentCollection {#95117 …}
    #variants: Doctrine\ORM\PersistentCollection {#95119 …}
    #options: Doctrine\ORM\PersistentCollection {#95123 …}
    #associations: Doctrine\ORM\PersistentCollection {#95121 …}
    #createdAt: DateTime @1751040181 {#95095
      date: 2025-06-27 18:03:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608621 {#95096
      date: 2025-08-08 01:17:01.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95107 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#96023
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95100}
        #id: 43309
        #name: "IEEE 980:2021"
        #slug: "ieee-980-2021-ieee00007038-243727"
        #description: """
          Revision Standard - Active.<br />\n
          The significance of oil-spillage regulations and their applicability to electric substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage in electric substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies to all types of insulating oil, fuel, and other oils typical of electrical substations.<br />\n
          It is not the intent of this guide to interpret government regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Note that much of the material and information in this guide is based on discussions, experiences, and research conducted by the IEEE Oil Containment Working Group. Part of this research includes industry surveys conducted in 1992 and 2012 in an effort to determine common practices for oil containment and control in electrical substations. Although generally not discussed in the body of this guide, the detailed survey results can be found within Annex C.<br />\n
          Containment, control, and mitigation of oil spills are a concern for owners and operators of electric substations. The environmental impact of oil spills and their mitigation is regulated by some governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate and the adverse community response to any spill is becoming increasingly unacceptable. This guide identifies some governmental regulations, the sources of oil spills, and typical methods and plans used to contain, control, and mitigate them.<br />\n
          Note that use of the term “oil” in this document includes mineral oil and other alternative insulating fluids.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95109 …}
    #channels: Doctrine\ORM\PersistentCollection {#95115 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95111 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95113 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95101 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95097
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1677106800 {#95098
      date: 2023-02-23 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1650405600 {#95099
      date: 2022-04-20 00:00:00.0 Europe/Paris (+02:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 82
    -documents: Doctrine\ORM\PersistentCollection {#95103 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95105 …}
  }
]
Attributes
[
  "showFullLabel" => false
]
Component
App\Twig\Components\ProductState {#96041
  +product: App\Entity\Product\Product {#95100
    #id: 12075
    #code: "IEEE00007038"
    #attributes: Doctrine\ORM\PersistentCollection {#95117 …}
    #variants: Doctrine\ORM\PersistentCollection {#95119 …}
    #options: Doctrine\ORM\PersistentCollection {#95123 …}
    #associations: Doctrine\ORM\PersistentCollection {#95121 …}
    #createdAt: DateTime @1751040181 {#95095
      date: 2025-06-27 18:03:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608621 {#95096
      date: 2025-08-08 01:17:01.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95107 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#96023
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95100}
        #id: 43309
        #name: "IEEE 980:2021"
        #slug: "ieee-980-2021-ieee00007038-243727"
        #description: """
          Revision Standard - Active.<br />\n
          The significance of oil-spillage regulations and their applicability to electric substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage in electric substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies to all types of insulating oil, fuel, and other oils typical of electrical substations.<br />\n
          It is not the intent of this guide to interpret government regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Note that much of the material and information in this guide is based on discussions, experiences, and research conducted by the IEEE Oil Containment Working Group. Part of this research includes industry surveys conducted in 1992 and 2012 in an effort to determine common practices for oil containment and control in electrical substations. Although generally not discussed in the body of this guide, the detailed survey results can be found within Annex C.<br />\n
          Containment, control, and mitigation of oil spills are a concern for owners and operators of electric substations. The environmental impact of oil spills and their mitigation is regulated by some governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate and the adverse community response to any spill is becoming increasingly unacceptable. This guide identifies some governmental regulations, the sources of oil spills, and typical methods and plans used to contain, control, and mitigate them.<br />\n
          Note that use of the term “oil” in this document includes mineral oil and other alternative insulating fluids.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95109 …}
    #channels: Doctrine\ORM\PersistentCollection {#95115 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95111 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95113 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95101 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95097
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1677106800 {#95098
      date: 2023-02-23 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1650405600 {#95099
      date: 2022-04-20 00:00:00.0 Europe/Paris (+02:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 82
    -documents: Doctrine\ORM\PersistentCollection {#95103 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95105 …}
  }
  +appearance: "state-active"
  +labels: [
    "Active"
  ]
  -stateAttributeCode: "state"
  -localeContext: Sylius\Component\Locale\Context\CompositeLocaleContext {#1833 …}
}
ProductMostRecent App\Twig\Components\ProductMostRecent 74.0 MiB 0.65 ms
Input props
[
  "product" => App\Entity\Product\Product {#95100
    #id: 12075
    #code: "IEEE00007038"
    #attributes: Doctrine\ORM\PersistentCollection {#95117 …}
    #variants: Doctrine\ORM\PersistentCollection {#95119 …}
    #options: Doctrine\ORM\PersistentCollection {#95123 …}
    #associations: Doctrine\ORM\PersistentCollection {#95121 …}
    #createdAt: DateTime @1751040181 {#95095
      date: 2025-06-27 18:03:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608621 {#95096
      date: 2025-08-08 01:17:01.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95107 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#96023
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95100}
        #id: 43309
        #name: "IEEE 980:2021"
        #slug: "ieee-980-2021-ieee00007038-243727"
        #description: """
          Revision Standard - Active.<br />\n
          The significance of oil-spillage regulations and their applicability to electric substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage in electric substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies to all types of insulating oil, fuel, and other oils typical of electrical substations.<br />\n
          It is not the intent of this guide to interpret government regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Note that much of the material and information in this guide is based on discussions, experiences, and research conducted by the IEEE Oil Containment Working Group. Part of this research includes industry surveys conducted in 1992 and 2012 in an effort to determine common practices for oil containment and control in electrical substations. Although generally not discussed in the body of this guide, the detailed survey results can be found within Annex C.<br />\n
          Containment, control, and mitigation of oil spills are a concern for owners and operators of electric substations. The environmental impact of oil spills and their mitigation is regulated by some governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate and the adverse community response to any spill is becoming increasingly unacceptable. This guide identifies some governmental regulations, the sources of oil spills, and typical methods and plans used to contain, control, and mitigate them.<br />\n
          Note that use of the term “oil” in this document includes mineral oil and other alternative insulating fluids.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95109 …}
    #channels: Doctrine\ORM\PersistentCollection {#95115 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95111 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95113 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95101 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95097
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1677106800 {#95098
      date: 2023-02-23 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1650405600 {#95099
      date: 2022-04-20 00:00:00.0 Europe/Paris (+02:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 82
    -documents: Doctrine\ORM\PersistentCollection {#95103 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95105 …}
  }
]
Attributes
[]
Component
App\Twig\Components\ProductMostRecent {#96115
  +product: App\Entity\Product\Product {#95100
    #id: 12075
    #code: "IEEE00007038"
    #attributes: Doctrine\ORM\PersistentCollection {#95117 …}
    #variants: Doctrine\ORM\PersistentCollection {#95119 …}
    #options: Doctrine\ORM\PersistentCollection {#95123 …}
    #associations: Doctrine\ORM\PersistentCollection {#95121 …}
    #createdAt: DateTime @1751040181 {#95095
      date: 2025-06-27 18:03:01.0 Europe/Paris (+02:00)
    }
    #updatedAt: DateTime @1754608621 {#95096
      date: 2025-08-08 01:17:01.0 Europe/Paris (+02:00)
    }
    #enabled: true
    #translations: Doctrine\ORM\PersistentCollection {#95107 …}
    #translationsCache: [
      "en_US" => App\Entity\Product\ProductTranslation {#96023
        #locale: "en_US"
        #translatable: App\Entity\Product\Product {#95100}
        #id: 43309
        #name: "IEEE 980:2021"
        #slug: "ieee-980-2021-ieee00007038-243727"
        #description: """
          Revision Standard - Active.<br />\n
          The significance of oil-spillage regulations and their applicability to electric substations are discussed; the sources of oil spills are identified; typical designs and methods for dealing with oil containment and control of oil spills are discussed; and guidelines for preparation of a typical Spill Prevention Control and Countermeasures (SPCC) plan are provided. This guide excludes polychlorinated biphenyl (PCB) handling and disposal considerations.<br />\n
          \t\t\t\t<br />\n
          This guide discusses the significance of oil spillage in electric substations; identifies the sources of oil spills; discusses typical designs and methods for dealing with oil containment and control of oil spills; and provides guidelines for preparation of a typical spill prevention control and mitigation plan. This guide applies to all types of insulating oil, fuel, and other oils typical of electrical substations.<br />\n
          It is not the intent of this guide to interpret government regulations or the applicability of the oil containment systems presented with respect to compliance to those regulations. Interpretation is left to each individual user.<br />\n
          Note that much of the material and information in this guide is based on discussions, experiences, and research conducted by the IEEE Oil Containment Working Group. Part of this research includes industry surveys conducted in 1992 and 2012 in an effort to determine common practices for oil containment and control in electrical substations. Although generally not discussed in the body of this guide, the detailed survey results can be found within Annex C.<br />\n
          Containment, control, and mitigation of oil spills are a concern for owners and operators of electric substations. The environmental impact of oil spills and their mitigation is regulated by some governmental agencies, necessitating increased attention in substations to the need for secondary oil containment. Beyond the threat to the environment, mitigation costs associated with oil spills continue to escalate and the adverse community response to any spill is becoming increasingly unacceptable. This guide identifies some governmental regulations, the sources of oil spills, and typical methods and plans used to contain, control, and mitigate them.<br />\n
          Note that use of the term “oil” in this document includes mineral oil and other alternative insulating fluids.
          """
        #metaKeywords: null
        #metaDescription: null
        #shortDescription: "IEEE Guide for Containment and Control of Oil Spills in Substations"
        -notes: "Active"
      }
    ]
    #currentLocale: "en_US"
    #currentTranslation: null
    #fallbackLocale: "en_US"
    #variantSelectionMethod: "match"
    #productTaxons: Doctrine\ORM\PersistentCollection {#95109 …}
    #channels: Doctrine\ORM\PersistentCollection {#95115 …}
    #mainTaxon: App\Entity\Taxonomy\Taxon {#8840 …}
    #reviews: Doctrine\ORM\PersistentCollection {#95111 …}
    #averageRating: 0.0
    #images: Doctrine\ORM\PersistentCollection {#95113 …}
    -supplier: Proxies\__CG__\App\Entity\Supplier\Supplier {#95060 …}
    -subscriptionCollections: Doctrine\ORM\PersistentCollection {#95101 …}
    -apiLastModifiedAt: DateTime @1754517600 {#95097
      date: 2025-08-07 00:00:00.0 Europe/Paris (+02:00)
    }
    -lastUpdatedAt: DateTime @1677106800 {#95098
      date: 2023-02-23 00:00:00.0 Europe/Paris (+01:00)
    }
    -author: ""
    -publishedAt: DateTime @1650405600 {#95099
      date: 2022-04-20 00:00:00.0 Europe/Paris (+02:00)
    }
    -releasedAt: null
    -confirmedAt: null
    -canceledAt: null
    -edition: null
    -coreDocument: "980"
    -bookCollection: ""
    -pageCount: 82
    -documents: Doctrine\ORM\PersistentCollection {#95103 …}
    -favorites: Doctrine\ORM\PersistentCollection {#95105 …}
  }
  +label: "Most Recent"
  +icon: "check-xs"
  -mostRecentAttributeCode: "most_recent"
  -localeContext: Sylius\Component\Locale\Context\CompositeLocaleContext {#1833 …}
}